{"id":21,"date":"2024-09-07T20:26:16","date_gmt":"2024-09-08T00:26:16","guid":{"rendered":"https:\/\/sites.bu.edu\/cryoem\/?page_id=21"},"modified":"2026-04-15T16:22:02","modified_gmt":"2026-04-15T20:22:02","slug":"educational-resources","status":"publish","type":"page","link":"https:\/\/sites.bu.edu\/cryoem\/educational-resources\/","title":{"rendered":"Educational Resources"},"content":{"rendered":"<h3>BU Glacios-2 Single Particle Analysis Protocol<\/h3>\n<p>Detailed protocol for Glacios-2 single particle analysis screening and data collection using Thermofisher EPU software<a href=\"\/cryoem\/files\/2024\/11\/20241115_BU_Glacios-2_screening_and_data_collection_protocol.docx\"><\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2026\/04\/20260415_Glacios-2_cryoEM_single_particle_analysis_screening_and_data_collection_protocol.docx\">20260415_Glacios-2_cryoEM_single_particle_analysis_screening_and_data_collection_protocol<\/a><a href=\"\/cryoem\/files\/2026\/04\/20260415_Glacios-2_cryoEM_single_particle_analysis_screening_and_data_collection_protocol.docx\"><\/a><\/p>\n<hr \/>\n<h3>BU Glacios 2 Tomography Protocol<\/h3>\n<p>Detailed protocol for Glacios-2 tomography analysis screening and data collection using Thermofisher Tomo software<a href=\"\/cryoem\/files\/2024\/11\/20241115_BU_Glacios-2_screening_and_data_collection_protocol.docx\"><\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2025\/11\/20251125_BU_Glacios-2_tomography_screening_and_data_collection_protocol.docx\">20251125_BU_Glacios-2_tomography_screening_and_data_collection_protocol<\/a><\/p>\n<hr \/>\n<h3>CryoEM 101 &amp; cryoET 101<\/h3>\n<p>Basic overview of cryoEM and cryoET with useful diagrams, videos, and images<\/p>\n<p><a href=\"https:\/\/cryoem101.org\/\">https:\/\/cryoem101.org\/<\/a><\/p>\n<hr \/>\n<h3>ThermoFisher Cryo-EM University<\/h3>\n<p>Comprehensive video series showing the full cryoEM pipeline<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/life-sciences\/learning-center\/cryo-em-university.html\">https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/life-sciences\/learning-center\/cryo-em-university.html<\/a><\/p>\n<hr \/>\n<h3>CryoSPARC Tutorial Videos<\/h3>\n<p>In-depth tutorial videos explaining how to use cryoSPARC for processing cryoEM data<\/p>\n<p><a href=\"https:\/\/guide.cryosparc.com\/processing-data\/tutorial-videos\">https:\/\/guide.cryosparc.com\/processing-data\/tutorial-videos<\/a><\/p>\n<hr \/>\n<h3>Caltech | Getting Started in Cryo-EM<\/h3>\n<p>Theory, technology, and sample preparation in Cryo-EM<\/p>\n<p><a href=\"https:\/\/cryo-em-course.caltech.edu\/\">https:\/\/cryo-em-course.caltech.edu\/<\/a><\/p>\n<hr \/>\n<h3>CryoSPARC Discussion Forum<\/h3>\n<p>Useful web forum to facilitate discussion on cryoEM data processing using the cryoSPARC software<\/p>\n<p><a href=\"https:\/\/discuss.cryosparc.com\/\">https:\/\/discuss.cryosparc.com\/<\/a><\/p>\n<hr \/>\n<h3>Other Resources<\/h3>\n<p><a href=\"\/cryoem\/files\/2025\/09\/EPU-User-Manual-v3.8-25-APR-2024.pdf\">EPU User Manual v3.8 25-APR-2024<\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2025\/09\/Tomography-User-Manual-v5.19-09-JUL-2024.pdf\">Tomography User Manual v5.19 09-JUL-2024<\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2024\/09\/Falcon4i_Apps_Note_v1.6.pdf\">Falcon4i_Apps_Note_v1.6<\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2025\/03\/Sherpa-User-Manual-7.13.pdf\">Sherpa User Manual 7.13<\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2024\/09\/ThermoFisher_Talos_Arctica__Glacios_Training_Packet.pdf\">ThermoFisher_Talos_Arctica_&amp;_Glacios_Training_Packet<\/a><\/p>\n<p><a href=\"\/cryoem\/files\/2025\/10\/Vitrobot-User-Manual-v103261-15-APR-2025.pdf\">Vitrobot User Manual v103261 15-APR-2025<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>BU Glacios-2 Single Particle Analysis Protocol Detailed protocol for Glacios-2 single particle analysis screening and data collection using Thermofisher EPU software 20260415_Glacios-2_cryoEM_single_particle_analysis_screening_and_data_collection_protocol BU Glacios 2 Tomography Protocol Detailed protocol for Glacios-2 tomography analysis screening and data collection using Thermofisher Tomo software 20251125_BU_Glacios-2_tomography_screening_and_data_collection_protocol CryoEM 101 &amp; cryoET 101 Basic overview of cryoEM and cryoET with useful [&hellip;]<\/p>\n","protected":false},"author":24032,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/pages\/21"}],"collection":[{"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/users\/24032"}],"replies":[{"embeddable":true,"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/comments?post=21"}],"version-history":[{"count":29,"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/pages\/21\/revisions"}],"predecessor-version":[{"id":262,"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/pages\/21\/revisions\/262"}],"wp:attachment":[{"href":"https:\/\/sites.bu.edu\/cryoem\/wp-json\/wp\/v2\/media?parent=21"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}